Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 188
Filtrar
1.
J Dent ; 142: 104823, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38145806

RESUMO

OBJECTIVE: To evaluate the effect of prolonged (P) polymerization time of a universal adhesive system applied in etch-and-rinse (ER) or self-etch (SE) strategies on the clinical performance of restorations in non-carious cervical lesions (NCCLs), after 36 months of clinical service. METHODS: A total of 140 restorations were randomly placed in 35 subjects according to the polymerization time groups: ER (10 s); ER-P (40 s); SE (10 s); and SE-P (40 s) at 1,200 mW/cm2. Composite resin was placed incrementally. The restorations were evaluated immediately and after 6, 12, 18, and 36 months using the FDI criteria. Data were analyzed using the Kaplan-Meier survival test for retention loss, and the Kruskal-Wallis' test for secondary outcomes (α = 0.05). RESULTS: After 36 months, 19 restorations were lost: ER 6, ER-P 2, SE 9, SE-P 2. The retention rates were 82.3% for ER; 94.1 % for ER-P; 73.5 % for SE; and 94.1 % for SE-P, with a significant difference between ER vs. ER-P and SE vs. SE-P, as well as ER vs. SE-P and ER-P vs. SE (p < 0.0001). Minor defects were observed in 18 restorations for the marginal staining criteria: ER 5, ER-P 2, SE 8, SE-P 3; and in 33 restorations for the marginal adaptation criteria: ER 11, ER-P 4, SE 12, and SE-P 6 (p > 0.05). No restorations showed recurrence of caries or postoperative sensitivity. CONCLUSIONS: A prolonged polymerization time of 40 s improves the clinical performance of the universal adhesive for both adhesive strategies evaluated, even after 36 months. CLINICAL SIGNIFICANCE: Prolonging the polymerization time of a universal adhesive from 10 to 40 s has been shown to improve its clinical performance when used in NCCLs.


Assuntos
Cimentos Dentários , Adesivos Dentinários , Humanos , Resinas Compostas/uso terapêutico , Adaptação Marginal Dentária , Falha de Restauração Dentária , Restauração Dentária Permanente , Adesivos Dentinários/uso terapêutico , Polimerização , Cimentos de Resina/uso terapêutico , Colo do Dente/patologia , Método Duplo-Cego
2.
J Esthet Restor Dent ; 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38014602

RESUMO

OBJECTIVE: This study evaluated the effect of bromelain and propolis extract on the bond strength (BS) of a universal adhesive system to eroded dentin. MATERIALS AND METHODS: Sixty human molars with exposed dentin were halved, with one half protected by composite resin and the other subjected to erosive treatment followed by remineralization. After the erosive treatment, the composite resin was removed, and the teeth were randomly assigned to three groups (n = 20): Adhesive-Control System; Br-10%; Pr-16%. Following the treatments, composite resin blocks were built on the dentin surfaces and sticks of 0.9 mm2 were obtained and stored in distilled water at 37°C for 24 h and 6 months. After these periods, the sticks underwent bond strength testing and the data were analyzed using 2-way ANOVA, Bonferroni test, p < 0.05. Fracture patterns were observed using light microscope and scanning electron microscopy. RESULTS: Irrespective of the substrate and aging duration, propolis demonstrated higher BS (p < 0.05) compared to the other treatments. Eroded dentin exhibited greater removal of the smear layer and dentinal tubules with a larger diameter than sound dentin, especially when treated with bromelain, resulting in the formation of resin tags. CONCLUSIONS: Propolis consistently promoted the highest bond strength, irrespective of aging or substrate. Eroded dentin treated with propolis, or bromelain exhibited a higher prevalence of non-adhesive fractures and resin tag formation. CLINICAL SIGNIFICANCE: Propolis shows promise for enhancing the longevity of adhesive restorations in eroded dentin due to its ability to promote high bond strength.

3.
Cureus ; 15(10): e46766, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37954744

RESUMO

OBJECTIVES: The adhesion of bonding agents and their longevity are of interest to dentistry. Microleakage remains the major cause of composite restoration failures, which in turn depends on bonding between the restorative material and tooth substrate. The objective of this study is to evaluate and compare the microleakage with total-etch, universal, and nano adhesive systems in Class V composite restorations, utilizing a dye penetration method. METHODS: Forty-five extracted premolars were included in the present study, and a Class V cavity on the facial surface of each tooth was prepared. The samples were divided into three groups of 15 teeth each depending on the bonding agents used, following which composite restoration was done. Specimens were thermocycled, and nail varnish was applied except around the restorations. Specimens were then immersed in 2% methylene blue for 24 hours and rinsed; sectioning was done and viewed under a stereomicroscope with 10X magnification. RESULTS: The mean microleakage score was reported to be significantly higher in the universal adhesive system in the self-etch mode (3.60 ± 0.55) when compared with the total-etch adhesive system (2.40 ± 0.55) and least in the nano adhesive system (1.20+.45) (p value <.05). CONCLUSION: The study findings revealed that nano adhesives showed lesser microleakage as compared to total-etch and universal adhesive systems. CLINICAL SIGNIFICANCE: The study strengthens the findings that the nano adhesives have reduced microleakage, resulting in better marginal integrity and increased longevity of restoration. This study signifies that an eighth-generation bonding agent is reported to be better than the other bonding agents used in this study.

4.
Clin Cosmet Investig Dent ; 15: 281-288, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37955001

RESUMO

Introduction: Matrix metalloproteinases enzymes (MMPs) can degrade the hybrid layer which can cause failure of composite restorations. Chlorhexidine gluconate 2% can reduce MMPs activity and increase the bond strength of the resin to dentin. Purpose: This study aims to determine the role of the duration of chlorhexidine gluconate 2% application on shear bond strength of a total-etch bonding agent. Methods: A total of 36 freshly extracted maxillary premolars were removed occlusally by one-third of the crown using a carborundum disc until the dentin was exposed. Specimens were divided into four groups n(9). The dentin surfaces were etched for 5s. Group A is the control group. In group B, chlorhexidine gluconate 2% was applied for 30s. In group C, chlorhexidine gluconate 2% was applied for 60s. In group D, chlorhexidine gluconate 2% was applied for 90s. The universal adhesive was applied afterwards and then followed by composite to the dentin surface. All specimens were stored in artificial saliva at 37°C for 24 hours. The shear bond strength was tested using a universal testing machine. Results: There was an increase in the shear bond strength of the bonding agent along with the additional application duration of chlorhexidine gluconate 2%. All groups gave higher MPa values than the control group. The shear bond strength in group A (control) was 12.64 MPa; Group B (30s of chlorhexidine) was 16.93 MPa; Group C (60s chlorhexidine) was 18.23 MPa; group D (90s of chlorhexidine) was 18.47MPa. Conclusion: Duration of chlorhexidine gluconate 2% application affects the shear bond strength of the bonding agent with the total-etch system. The effective duration of chlorhexidine gluconate 2% for the restorative procedure is 60 seconds.

5.
Int J Clin Pediatr Dent ; 16(Suppl 1): S63-S66, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37663220

RESUMO

Aim: To compare the effect of salivary contamination on the shear bond strength (SBS) of seventh- and eighth-generation adhesives. Materials and methods: Specimens were randomly divided into group I and group II, subdivided into three subgroups of 11 samples. Subgroup IA-seventh-generation uncontaminated (control); adhesive; air-dried; light cured. Subgroup IB-seventh-generation adhesive; saliva application, air-dried; light cured. Subgroup IC-seventh-generation adhesive; saliva application, air-dried, reapplication of adhesive, air-dried, light cured. Subgroup IIA- eighth-generation uncontaminated (control); adhesive, air-dried; light cured. Subgroup IIB- eighth-generation adhesive; saliva application, air-dried; light cured. Subgroup IIC-eighth-generation adhesive, saliva application, air-dried, reapplication of adhesive, air-dried; light cured. Following bonding procedure, composite resin restoration was done and subjected to SBS analysis. Results: Mean SBS of eighth-generation adhesive was higher compared to seventh with and without saliva contamination. Reduction of SBS in seventh- and eighth-generation after saliva contamination was regained by reapplication of adhesive, which was less compared to the control [statistically significant (p < 0.05) for seventh and statistically not significant for eighth-generations]. Conclusion: The eighth-generation adhesives show better SBS with and without saliva contamination and reapplication of eighth-generation adhesives significantly improved the SBS close to the control. Clinical significance: Single-step self-etch adhesives are the adhesives which are currently used for bonding composite restorations to dentin. The adhesive bond strength can be adversely affected by moisture contamination, especially by saliva, which can lead to failure of restoration. So, it is imperative to study a material which gives better bond strength and is less affected by salivary contamination and effect of decontamination to regain the bond strength. The study concluded that eighth-generation adhesives showed higher mean SBS with and without saliva contamination and reapplication of eighth-generation adhesives significantly improved the bond strength close to the control group. How to cite this article: Mohan MC, Geetha P, Soman D, et al. The Effect of Salivary Contamination on the Shear Bond Strength of Seventh- and Eighth-generation Adhesive Systems. Int J Clin Pediatr Dent 2023;16(S-1):S63-S66.

6.
Eur J Oral Sci ; 131(5-6): e12947, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37501189

RESUMO

This study evaluated the effect of pretreatment with limonene and/or biosilicate on the bond strength of a universal adhesive system in self-etch mode to dentin. Occlusal cavities were prepared in 80 human molars and the teeth were randomly allocated to one of four groups (n = 20), according to the pretreatment regimens applied before the adhesive. The pretreatments were (i) Control, no pretreatment, (ii) LIM, 0.5% limonene; (iii) Bio, 10% biosilicate; and (iv) LIMBio, LIM + Bio. After adhesive application and restoration, the specimens were sectioned into sticks, separated, and stored in distilled water at 37°C for 24 h or 6 months. Microtensile bond strength test was carried out and measurements were compared across pretreatment groups and storage times. Fracture patterns and adhesive interfaces were observed. Loss of dry mass was calculated (n = 10). There was no statistically significant difference in the bond strength between the groups and the most prevalent fracture pattern was the non-adhesive. LIM and LIMBio resulted in more open dentinal tubules. LIM and Bio, whether separate or combined, showed particles of those substances, which decreased in size and number after 6 months. All groups lost mass weight after treatment, with no statistically significant differences between them. Limonene and biosilicate pretreatment did not affect the bond strength to dentin of the universal adhesive system, but resulted in more non-adhesive fractures, even after 6 months.


Assuntos
Colagem Dentária , Adesivos Dentinários , Humanos , Adesivos Dentinários/química , Limoneno/farmacologia , Cimentos de Resina/química , Colagem Dentária/métodos , Teste de Materiais , Dentina , Cerâmica , Resistência à Tração
7.
Dent Mater ; 39(9): 820-830, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37481368

RESUMO

OBJECTIVES: This study aimed to evaluate the effect of copper nanoparticles (CuNp) on the clinical performance of a universal adhesive system used as an etch-and-rinse or self-etch strategy. METHODS: A total of 216 class V (non-carious lesions) restorations were randomly placed in 36 subjects according to the following groups: ERcu, adhesive in etch-and-rinse with 0.1% CuNp; ERct, adhesive in etch-and-rinse without CuNp; SEcu, adhesive in self-etch with 0.1% CuNp; and Sect, adhesive in self-etch without CuNp. Restorations were evaluated at baseline and at 6, 12, 18, 36, and 48 months, using the FDI and USPHS criteria. Appropriate statistical analyses were performed (α = 0.05). RESULTS: After 48 months, 14 restorations were lost (two for ERcu, five for SEcu, and seven for SEct) and the retention rates (95% confidence interval [CI]) were 74.1% for ERcu (95% CI 61.1-83.8); 81.5% for ERct (95% CI 69.2-89.6); 64.8% (95% CI 51.5-76.2) for SEcu; and 64.8% (95% CI 51.5-76.2) for SEct, with statistical differences between SEct vs. ERct and SEcu vs. ERct (p < 0.05). No significant differences between the groups were observed when the secondary parameters were evaluated (p > 0.05). Nineteen restorations (two for ERcu, two for ERct, six for SEcu, and nine for SEct) showed minor marginal staining, and 44 restorations (7 for ERcu, 8 for ERct, 14 for SEcu, and 15 for SEct) presented minimal marginal adaptation defects. SIGNIFICANCE: This is the first long-term clinical trial to show that the addition of CuNp to a universal adhesive system does not affect clinical performance.


Assuntos
Cárie Dentária , Nanopartículas , Estados Unidos , Humanos , Cobre , Projetos de Pesquisa , Coloração e Rotulagem
8.
Clin Oral Investig ; 27(6): 2495-2511, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37017757

RESUMO

OBJECTIVES: This meta-analysis aimed to elucidate the effects of various acid etching patterns on the sensitivity of teeth and their clinical effectiveness following composite resin repair. MATERIALS AND METHODS: PubMed, Cochrane Library, Web of Science, and Embase databases were searched for relevant studies on the postoperative sensitivity (POS) of composite resin restorations after using different bonding systems. The retrieval was from the inception of the databases to August 13, 2022, with no filter of written language. Literature screening was conducted by two independent researchers. The Cochrane risk-of-bias assessment tool was adopted for quality evaluation, and Stata 15.0 for analysis. RESULTS: Twenty-five randomized controlled trials were included in the present study. Following resin composite restoration, 1309 restorations were bonded by self-etching (SE) adhesives, whereas 1271 restorations were bonded by total-etching (TE) adhesives. The meta-analyses showed that there is no evidence to prove the SE and TE will affect POS at present when measured using the modified United States Public Health Service (USPHS) criteria [RR = 1.00 (95% CI: 0.96, 1.04)], the World Dental Federation (FDI) [RR = 1.06 (95% CI: 0.98, 1.15)], or the visual analog scale (VAS) [SMD = 0.02 (95% CI: -0.15, 0.20)] scales. At a certain follow-up time, TE adhesives provide better outcomes in terms of color match, marginal staining, and marginal adaptation. In other words, TE adhesives have better esthetic results. CONCLUSIONS: The type of bonding technique (ER and SE) does not affect the risk and degree of POS in class I/II and class V restorations. Further research is required to verify whether these findings apply to different forms of composite resin restorations. CLINICAL RELEVANCE: Besides the fact that TE barely increase postoperative sensitivity, it also yields superior cosmetic results.


Assuntos
Resinas Compostas , Cimentos Dentários , Resinas Compostas/uso terapêutico , Adesivos Dentinários , Cimentos de Resina , Restauração Dentária Permanente/métodos , Condicionamento Ácido do Dente/métodos , Estética Dentária , Adaptação Marginal Dentária
9.
J Esthet Restor Dent ; 35(7): 1030-1038, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36971211

RESUMO

OBJECTIVE: We aimed to introduce the concept of "Selective adhesive luting-SAL" which is explained through clinical steps and supported by preliminary laboratory evidence. CLINICAL CONSIDERATIONS: Cementation with rubber dam is difficult to perform in case of short abutment teeth and/or subgingival crown margins. By means of universal resin cements/universal adhesive systems, which can be employed in self-adhesive as well as adhesive luting procedures, this paper presents a novel technique allowing clinicians to perform reliable cementation where rubber dam isolation is difficult. The SAL technique entails the application of a universal adhesive system only on easily accessible abutment surfaces, enabling simultaneous adhesive and self-adhesive luting in different portions of the abutment. The SAL clinical workflow is explained through prosthodontic rehabilitation of maxillary right central incisor affected by microdontia and restored with a lithium-disilicate crown. Furthermore, our laboratory microshear bond strength study supports the rationale behind SAL application demonstrating higher bond strength even when the adhesive resin is placed only on one portion of the cementation substrate. CLINICAL SIGNIFICANCE: This article advocates the application of SAL technique in clinical situations where effective adhesive luting is uncertain, since it can improve the adhesion between the tooth and universal resin cements.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Cimentos Dentários/química , Cimentação/métodos , Coroas , Teste de Materiais , Propriedades de Superfície
10.
Polymers (Basel) ; 15(2)2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36679164

RESUMO

The aim of this study is to compare the marginal seal and tensile bond strength (TBS) of prostheses fixed to enamel-dentin using different adhesive systems. Resin-composite inlays directly fabricated from Class V cavities of extracted human molars/premolars and mini-dumbbell-shaped specimens of bonded enamel-dentin were prepared for microleakage and tensile tests, respectively. Four adhesive systems were used: primerless-wet (1-1 etching for 10-, 30-, or 60-s, and 4-META/MMA-TBB), primer-moist (All-Bond2 + Duolink or Single-Bond2 + RelyX ARC), self-etch (AQ-Bond + Metafil FLO), and dry (Super-Bond C&B) bonding. Dye penetration distance and TBS data were recorded. Failure modes and characteristics of the tooth-resin interface were examined on the fractured specimens. All specimens in 10-, 30-, and 60-s etching primerless-wet, Super-Bond, and AQ-Bond had a microleakage-free tooth-resin interface. Primer-moist groups showed microleakage at the cementum/dentin-resin margin/interface. Significantly higher TBSs (p < 0.05) were recorded in primer-less-wet and Super-Bond groups with the consistent hybridized biopolymer layer after the chemical challenge and mixed failure in tooth structure, luting-resin, and at the PMMA-rod interface. There was no correlation between microleakage and TBS data (p = −0.148). A 1−3 µm hybrid layer created in the 10−60 s primerless-wet technique, producing complete micro-seal and higher tensile strength than enamel and cured 4-META/MMA-TBB, may enhance clinical performances like Super-Bond C&B, the sustainable luting resin.

11.
Dent Mater J ; 42(1): 121-132, 2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36351598

RESUMO

This study investigated the enamel and dentin bond durability of a two-step adhesive system, using a universal adhesive-derived primer (G2-Bond Universal [GU]), and compared it with the two conventional, two-step, self-etch adhesive systems (Clearfil SE Bond 2 [CS] and OptiBond XTR [OX]) under thermal cycling (TC) and long-term water storage (WS). The shear bond strengths to bovine enamel and dentin were determined using the etch-and-rinse and self-etch modes. Twelve specimens per test group were prepared and further divided into the following subgroups: 1) subjected to TC, 2) long-term WS, and 3) WS for 24 h (baseline). The enamel and dentin bond durability of GU was superior to those of CS and OX in different etching modes and under different degradation conditions. The latest two-step adhesive system, which utilizes universal adhesives' benefits in its primer, might offer durable clinical bonding performances and can be widely used in a clinical setting.


Assuntos
Colagem Dentária , Cimentos Dentários , Animais , Bovinos , Adesivos Dentinários/química , Teste de Materiais , Dentina , Cimentos de Resina/química , Água , Resistência ao Cisalhamento
12.
Spectrochim Acta A Mol Biomol Spectrosc ; 285: 121869, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36116411

RESUMO

The hydroxyl-terminated polybutadiene (HTPB) propellants with high level of solid loadings from 80 wt% to 90 wt% consist of aluminum (Al) powder, ammonium perchlorate (AP) and HTPB. The Al/AP/HTPB adhesive system full of solid grains appears high viscosity against flow. Therefore, the mixing is a crucial procedure in the production as it directly affects the structural integrity of the finished product. This work focused on the feasibility of tracking the blend homogeneity of Al/AP/HTPB adhesive system in the mixing process through using the near-infrared (NIR) spectroscopy and orthogonal partial least squares discrimination analysis (OPLS-DA). The OPLS-DA classification models were created by variable selection, spectral pretreatment and latent variables (LVs) optimization. It had been demonstrated that the developed models presented an excellent predictability with the root mean square error of cross-validation (RMSECV) for slurries in Ⅰ, Ⅱ groups of 0.1261 and 0.0789, respectively. Meanwhile, the well-fitted models for slurries in Ⅰ, Ⅱ groups with the squared correlation coefficient (R2) of 0.806 and 0.980, exhibited separately an acceptable predictive capability with the predictive squared correlation coefficient (Q2) > 0.5. Furthermore, Euclidean distance and move block standard deviation (MBSD) as reference methods were used to validate the predictive performance of the developed models with respect to the blend homogeneity of HTPB propellant slurry. The experimental results showed that the terminal time for each batch of slurry reaching to ideal uniformity predicted by Euclidean distance/MBSD and OPLS-DA were both at 26-30 min. Therefore, it had been proved that the method we proposed was a potential tool to monitor the variation of the uniform state of HTPB propellant slurry in the mixing process.

13.
J Esthet Restor Dent ; 35(1): 48-55, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36325593

RESUMO

OBJECTIVE: To evaluate the effect of rubber dam isolation on shear bond strength of two different adhesive systems to enamel. MATERIALS AND METHODS: The mesial, distal, lingual, and vestibular enamel surfaces of thirty human third molars were prepared (total n = 120). A custom splint was made to fit a volunteer's maxilla, holding the specimens in place in the oral cavity. Four composite resin cylinders were bonded to each tooth with one of two bonding agents (OptiBond FL and Prime&Bond active) with or without rubber dam isolation. Shear bond strength was tested in a universal testing machine and failure modes were assessed. Significance level for statistical analyses was set at 5%. RESULTS: All pairwise comparisons revealed statistical differences (p < 0.05). The highest mean shear bond strength values were obtained in rubber dam experimental groups, regardless of the adhesive system. Group OptiBond FL with rubber dam presented the highest mean bond strength values. Fracture modes for specimens bonded without rubber dam isolation were adhesive and cohesive within enamel, while rubber dam experimental groups revealed only cohesive fractures. CONCLUSIONS: Absolute isolation with rubber dam increases bond strength to enamel, independent of the adhesive system. The three-step total-etch system OptiBond FL provided significantly higher bond strength values than Prime&Bond active under both experimental conditions. CLINICAL SIGNIFICANCE: Rubber dam isolation has a significant effect on bond strengths to enamel, independent of the adhesive system. Its application is, therefore, advised whenever adhesive procedures are performed. A filled three-step etch-and-rinse adhesive performed superiorly, with or without rubber dam isolation, when bonding to enamel compared to an isopropanol-based universal adhesive.


Assuntos
Colagem Dentária , Humanos , Diques de Borracha , Cimentos de Resina/química , Resinas Compostas/química , Esmalte Dentário , Teste de Materiais , Adesivos Dentinários/química
14.
J Conserv Dent Endod ; 26(5): 525-529, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38292373

RESUMO

Aim: To determine the effect of three different dentin hypersensitivity treatment procedures on the microtensile bond strength of etch and rinse and self-etch adhesive system. Materials and Methods: Eighty extracted intact human permanent lower premolars were decoronated, and dentin was exposed on the buccal surface. The teeth were randomly assigned to two experimental groups of 40 teeth each: etch and rinse system or self-etch system. The 40 samples assigned were further randomly assigned to four desensitizing treatment subgroups: Control, Gluma, NovaMin, and GC tooth Mousse with 10 samples per subgroup. Desensitizing treatment was performed two times each day for 2 weeks respectively. The exposed dentin was subjected to etch and rinse or self-etch adhesive system bonding agent as per the group and restored using composite to 4-mm thickness. Samples were then subjected to universal testing machine for microtensile bond strength. Results: The bond strength to the dentin obtained with etch and rinse adhesive system group where significantly higher (P < 0.05) when compared to self-etch adhesive system. However, there was no significant effect of the desensitizing agent on the microtensile bond strength in its own. Scanning electron microscope imaging reviled tubular occlusion in all specimens treated with desensitizer. Conclusion: The bond strength was majorly impacted by the type of adhesive system used. While the desensitizing agents used in the study had little or no adverse effect on the bond strength of composites to dentin surface.

15.
Saudi Dent J ; 34(8): 779-787, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36570578

RESUMO

This study aimed at comparing shear-bond strength (SBS) of different self-etching adhesive systems (Clearfil S3 Bond Plus, G-Premio BOND and IBond) to dentin without or with diode-laser irradiation before photo-polymerization and to determine the effect of storage and thermo-cycling on SBS of adhesive systems. METHODS: The buccal surface of 84 extracted maxillary premolars was grounded to create flat surface. The specimens were allocated into 3 groups (n = 28) depending upon the adhesive systems, then each group was divided into two sub-group (I, II) (n = 14). After the placement of respective adhesive systems on the flat surface, adhesive system in group I was photo-polymerized immediately, while in group II, the adhesive systems were exposed to diode-laser before photo-polymerization. Composite cylinder (4 mm in diameter and 2 mm height) was built on the flat surface of each specimen. Then group I and II were divided into two sub-groups (n = 7) according to the storage time and thermo-cycling (1 day without thermo-cycling or 72 days with thermo-cycling) then all the specimens were stored in distilled water. The SBS was measured at the end of storage period. ANOVA, Duncan's Multiple Range Test and independent t-test "P ≤ 0.05" were used for data analysis. RESULTS: G-premio BOND showed the highest mean value of SBS followed by Clearfil S3 Bond plus without significant difference between them, while IBond revealed the least mean value. Laser irradiation had positive effect on the bond-strength of all tested adhesive systems. The results also showed that the storage with thermo-cycling had negative effect on the bond-strength in groups without laser irradiation for all tested adhesive systems, while for groups with laser irradiation, the reduction in the bond-strength of all tested adhesive systems was not significant. CONCLUSION: Diode-laser application prior to photo-polymerization of self-etch adhesive systems significantly increased the bond-strength to dentin and can increase the durability of composite adhesion.

16.
Acta odontol. latinoam ; 35(3): 206-213, Dec. 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1419947

RESUMO

ABSTRACT Aim: This study evaluated the influence of chitosan added to a universal adhesive system used in totaletch (TE) or self-etch (SE) mode on dentin permeability, and on the micromorphology of the adhesive layer. Materials and Method: Dentin discs were obtained from human third molars and randomly distributed according to bonding strategy (TE or SE), and to whether or not 1% chitosan (C) was added to a universal adhesive system (Single Bond Universal/3M ESPE), to create the following groups (n=10): TE, TEC, SE, and SEC. Dentin permeability was measured at baseline and after application of dentin treatments. The surface of the adhesive layer (AL) and the dentin adjacent to the AL were examined under a scanning electron microscope. Results: There were no significant differences in permeability percentage between the groups with and without C (TE and SE versus TEC and SEC) (p>0.05; Mann Whitney test). Dentin permeability was lower when the adhesive system was applied in the SE mode, regardless of the addition of C. The micromorphology of the AL surface showed irregularities, and a greater degree of porosity, when the adhesive system was applied in the SE mode, regardless of chitosan addition. There was a greater depth of penetration of the adhesives into the dentin adjacent to the AL in both the TE and TEC groups. Chitosan added to the adhesive system did not influence dentin permeability. Conclusions: The self-etch strategy led to lower dentin permeability, and to more irregularities on the surface of the adhesive layer.


RESUMO Objetivo: Este estudo avaliou a influência da quitosana adicionada a um sistema adesivo universal usado no modo total-etch (TE) ou self-etch (SE) na permeabilidade dentinária e na micromorfologia da camada adesiva. Materiais e método: Discos de dentina foram obtidos de terceiros molares humanos e distribuídos aleatoriamente de acordo com a estratégia de união (TE ou SE), e para incorporação ou não de quitosana a 1% (Q) em um sistema adesivo universal (Single Bond Universal/3M ESPE), para obter os seguintes grupos (n=10): TE, TEQ, SE e SEQ. A permeabilidade da dentina foi medida no início e após a aplicação dos tratamentos de dentina. A superfície da camada adesiva (CA) e a dentina adjacente à CA foram examinadas em microscópio eletrônico de varredura. Resultados: Não houve diferenças significativas no percentual de permeabilidade entre os grupos com e sem Q (TE e SE versus TEQ e SEQ) (p>0,05; teste de Mann Whitney). Houve um menor percentual de permeabilidade dentinária quando o sistema adesivo foi aplicado no modo SE, independentemente da incorporação de Q. A micromorfologia da superfície da CA apresentou irregularidades e maior grau de porosidade quando o sistema adesivo foi aplicado no modo SE, independentemente da adição de Q. Houve maior profundidade de penetração dos adesivos na dentina adjacente à CA nos grupos TE e TEQ. A quitosana adicionada ao sistema adesivo não influenciou a permeabilidade dentinária. Conclusões: A estratégia autocondicionante levo

17.
Materials (Basel) ; 15(22)2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36431740

RESUMO

The study aimed to evaluate the influence of the manipulation surfaces on the physical properties of one-step self-etch adhesives (1-SEAs). Scotchbond Universal (SBU), Clearfil Universal Bond Quick ER (UBQ), and an experimental adhesive (UBQexp) were manipulated on different surfaces: manufacturer's Teflon-based dispensing dish (TD) or hydroxyapatite plate (HA). After manipulation of the adhesives, the pH of each 1-SEA was measured. Samples of each adhesive/manipulation surface were prepared and subjected to water sorption (WS)/solubility (SL) and flexural strength tests. The modulus of elasticity (E) was measured in dry and wet conditions before and after 24 h water storage, and the percentage of variation of E (ΔE) was calculated. Results were analyzed using the t-test with Bonferroni corrections (α = 0.05). When adhesives were manipulated on the HA plate, there was a significant increase in the adhesives' pH. WS and SL of all 1-SEAs decreased when the HA was used. Only SBU showed higher flexural strength when manipulated on the HA compared to the manipulation on TD under dry and wet conditions. For each 1-SEA, the use of HA resulted in significantly higher E in dry and wet conditions. ΔE of all adhesives was smaller with the manipulation on HA than on TD. It was concluded that the manipulation of 1-SEA on a hydroxyapatite plate considerably affected the adhesives' properties.

18.
Open Biol ; 12(8): 220103, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35975651

RESUMO

Sea stars adhere strongly but temporarily to underwater substrata via the secretion of a blend of proteins, forming an adhesive footprint that they leave on the surface after detachment. Their tube feet enclose a duo-gland adhesive system comprising two types of adhesive cells, contributing different layers of the footprint and de-adhesive cells. In this study, we characterized the catalogue of sea star footprint proteins (Sfps) in the species Asterias rubens to gain insights in their potential function. We identified 16 Sfps and mapped their expression to type 1 and/or type 2 adhesive cells or to de-adhesive cells by double fluorescent in situ hybridization. Based on their cellular expression pattern and their conserved functional domains, we propose that the identified Sfps serve different functions during attachment, with two Sfps coupling to the surface, six providing cohesive strength and the rest forming a binding matrix. Immunolabelling of footprints with antibodies directed against one protein of each category confirmed these roles. A de-adhesive gland cell-specific astacin-like proteinase presumably weakens the bond between the adhesive material and the tube foot surface during detachment. Overall, we provide a model for temporary adhesion in sea stars, including a comprehensive list of the proteins involved.


Assuntos
Proteínas , Estrelas-do-Mar , Adesivos/metabolismo , Animais , Hibridização in Situ Fluorescente , Proteínas/química , Estrelas-do-Mar/metabolismo
19.
Eur Oral Res ; 56(2): 55-60, 2022 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-36003840

RESUMO

Purpose: This study aimed to investigate the effect of five porcelain repair systems on shear bond strength in composite and zirconia infrastructures and to identify the bond failure mode after thermocycling. Materials and methods: Disk-shaped zirconia samples (n=50) were divided into five groups (n=10) according to repairing system type. Each repair system was applied to the zirconium samples and a hybrid composite was used for repairing. Shear bond testing of all groups was carried out using a universal testing machine after thermocycling. Results: Repair systems demonstrated no significant difference in repairing zirconia except Single Bond. Single Bond was the weakest in repairing the infrastructures. The highest and lowest mean bond strength values for the zirconia groups were 18,91 MPa and 3,63 MPa, respectively. Conclusion: The three repair systems, Ivoclar, Clearfil, and Bisco, were more effective than the Single Bond and Ultradent repair systems in repairing zirconia, and their bond failure modes were both mixed and adhesive.

20.
Photodiagnosis Photodyn Ther ; 39: 102998, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35798290

RESUMO

AIM: The current study aimed to evaluate the efficacy of chlorhexidine (CHX), phycocyanin photosensitizer (PC), green tea extract (GTE), and propolis (PP) on the adhesive bond integrity and microleakage of caries-affected dentin (CAD) using etch and rinse adhesive system. MATERIAL AND METHODS: A sum of 80 extracted human mandibular molars was collected and assessed using ICDAS criteria. Randomly CAD samples were treated with different disinfectants (n = 20) each CHX, PC, GTE, and PP. After ensuring disinfection, specimens were rehabilitated with bulk-fill composite resin employing etch and rinse adhesive system. SBS testing was performed by engaging (n=10) specimens in a universal testing machine. Microleakage analysis was performed by using the dye penetration technique.A stereomicroscope under 40× magnification was utilized for analyzing failure modes. Statistical analysis was accomplished by using the ANOVA and Tukey's post hoc tests (p<0.05). RESULTS: Highest bond strength was displayed by CAD disinfection with CHX and bonded to resin cement (15.33 ± 0.14 MPa). Whereas, the lowest SBS bond value was presented by Group 2 dentin surface disinfection with PC. CAD disinfected with GTE, PP and CHX demonstrated comparable SBS(p>0.05). The maximum microleakage score was exhibited when CAD bonded to resin cement disinfected with PP. While the minimum microleakage score was unveiled CAD bonded to resin cement sanitized with CHX CONCLUSION: Caries-affected dentin bonded to resin cement, chlorhexidine exhibited the highest adhesive shear bond strength with a minimal microleakage score using etch and rinse adhesive system.


Assuntos
Fotoquimioterapia , Própole , Adesivos , Clorexidina/farmacologia , Resinas Compostas/química , Suscetibilidade à Cárie Dentária , Dentina , Humanos , Teste de Materiais , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Cimentos de Resina , Chá
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...